Multi-functional E1/Datacom Tester
GAO A0020006

Overview – Multi-functional E1/Datacom Tester

This full-featured E1/Datacom Tester is designed for the installation, acceptance testing and daily maintenance of digital networks. The E1/Datacom tester performs channel tests, alarm analysis, fault location and signal analysis. In addition, this tester provides various protocol converters with one-way and bi-directional bit-error-rate (BER) test functions.

Key Features – Multi-functional E1/Datacom Tester

  • Handheld design; easy-to-use
  • Full-featured measurements of E1, Datacom and Protocol Converter
  • High resolution backlit LCD
  • Smart menu navigation
  • Extensive error and alarm generation, detection and indication
  • Histogram analysis of alarm and error events
  • Save/Recall of up to 10 user-defined setups and 10 sets of results
  • Up to 6 hours operation from a single battery charge
  • Both built-in Ni-MH rechargeable batteries and smart charger circuitry
  • Upgradable software via an integrated RS232C interface
  • Test results can be uploaded, conserved and printed through the included software

Basic Functions - Multi-functional E1/Datacom Tester

E1 BER Tester Capability

  • 75 Ω and 120 Ω line interfaces
  • HDB3 and AMI line codes
  • Out-of-service 2 Mb/s, N×64 kb/s BER testing
  • In-service framed and unframed testing
  • Frame data control and monitoring
  • Time slot activity monitoring
  • Built-in 64 kb/s tone channel listen capability
  • CAS and CCS signaling generation and monitoring
  • Round trip delay measurement
  • APS delay measurement
  • Extensive error and alarm generation
  • VF tone generation and measurement
  • Frequency, clock slip and level measurement
  • Up to ±999 ppm transmit clock deviation
  • Clock source: Internal, Interface or External 2M clock/signal (optional)
  • Real-time transmission circuit open/short indication

Datacom Testing

  • Datacom (V.24, V.35, V.36, X.21, RS-449, RS-485, EIA-530 and EIA-530A) interfaces for BER testing
  • ASYNC BER testing with baud rate 50 b/s to57.6 b/s
  • SYNC BER testing with data rate 1.2 kb/s to 2.048 Mb/s
  • DTE or DCE emulation mode
  • SYNC clock source and sense selection
  • Frequency measurement
  • Handshaking signals control and monitoring

G.703 CO Testing

  • G.703 CO 64 kb/s BER testing
  • Octet timing control and monitoring
  • Frequency and offset measurement
  • Clock source: Internal, Interface

Protocol Converter Testing

  • E1-Datacom SYNC 64k or N×64 kb/s BER testing
  • E1-G.703 CO SYNC 64 kb/s BER testing
  • Frequency and offset measurement
  • Handshaking signals monitoring
  • E1 frame data monitoring

Other Functions

  • Real-time clock
  • Test pattern: PRBS, Fixed Code and 16 bit user word
  • Error injection: Single and Fixed Rate
  • Manual and auto-timer measurement
  • ITU-T G.821, G.826, and M.2100 performance analysis
  • Self-check and keyboard testing function

Technical Specifications – Multi-functional E1/Datacom Tester

Item
Description
E1
Internal Clock
2048 kb/s ±10 ppm
Frequency Deviation
±999 ppm
Line Interface
75 Ω (Unbalanced), 120 Ω (Balanced); High Input Impedance >2 KW
Line Code
HDB3, AMI
Framing
Unframed, PCM30, PCM30CRC, PCM31, PCM31CRC
Level Measurement
-43 dB to 2.5 dB
Tx Clock Source
Internal, Interface and External 2 MHz clock or signal (option)
Frequency Measurement
Accuracy:±1 Hz
Offset Measurement
Accuracy:±1 ppm
Range:-999 ppm to 999 ppm
VF Injection
Frequency: 200 Hz to 3400 Hz;Step:10 HZ
Level: -60 dBm to 3 dBm
VF Measurement
Frequency: 200 Hz to 3400 Hz, Accuracy: ±1 Hz
Level range : -60.00 dBm to 3.14 dBm
-60.00 dBm to 21.00 dBm, accuracy: ±2.87 dBm
-20.00 dBm to 3.14 dBm, accuracy: ±0.21 dBm
Delay measurement
Accuracy:±1 us
G.703 CO
Line Rate
64 kb/s±100 ppm
Line Interface
120 W, balanced
Line Code
AMI
Datacom
Line Interfaces
V.24, V.35, V.36, X.21, RS-449, RS-485, EIA-530, EIA-530A
Data Rate
ASYNC
50 bit/s, 75 bit/s, 150 bit/s, 300 bit/s, 600 bit/s, 1.2 kb/s, 2.4 kb/s, 4.8 kb/s, 9.6 kb/s, 19.2 kb/s, 38.4 kb/s, 57.6 kb/s
SYNC
1.2 kb/s, 2.4 kb/s, 4.8 kb/s, 9.6 kb/s, 19.2 kb/s, 38.4 kb/s, N×64 kb/s ( N=1 to 32)
Test Patterns
PRBS
223 -1, 220 -1, 215 -1, 211 -1, 29 -1, 26 -1
Fixed Code
1111, 0000, 1010
16-BIT
User Programmable Word
LED Alarm Indicators
Signal Loss, AIS, Frame Loss, MFrame Loss, Pattern Loss, Remote Alarm, Error, Clock Slip, Octet Loss, Low Battery
Error Injection
Type: BIT, FAS, CRC4, CODE, E-BIT
Single, Fixed Rate : 10-2 , 10-3 , 10-4 , 10-5 , 10-6 , 10-7
Performance Analysis
ITU-T G.821, G.826 and M.2100
Display
240x160 pixel backlight monochromatic LCD
Serial Port
RS-232C
Rechargeable Batteries
5×1.2 V AA Ni-MH batteries, continuous working for 6 hours
Recharge Time
Approx. 2 hours
AC Power Adapter
Input: 100 V to 240 V AC, 50/60 Hz
Output: 12 V DC/1.5 A
Test ManagerTM
WIN98/ME/2000/XP/NT
Dimensions
243 mm×90/128 mm×60 mm
Operating Temperature
0 °C to 50 °C
Storage Temperature
-20 °C to 70 °C
Humidity
5 % to 95 % non-condensing
Weight
Approx. 700 g